MULTI-TURN ELECTRIC DRIVESПЭМ

MULTI-TURN ELECTRIC DRIVESПЭМ

Multi-turn electric drives ПЭМ are designed to transfer torque to valves during their rotation for one or more turns.These drives are designed to activate shut-off and regulating valves within the systems of automatic process control according to control signals of control devices.

Versions:

  • General industrial,
  • Explosion-proof,
  • For nuclear power plants.

Multi-turn electric drives perform the following functions in shut-off/start-up mode:

  • Remote or manual shut-off or start-up of valves;
  • Remote shutdown of valves in any intermediate position.
  • Indication of rate of opening (closing) of valve trim on local indicator scale;
  • Signal to shutoff motor if valve limit positions, or the set output shaft torque is reached, or moving parts of the valve get jammed;
  • Setting and adjustment of torque;
  • Generation of analogue or digital signal proportional to valve trim position for use in signalling/control circuits, or signal transfer through RS-485 interface (ПЭМ-А 100, ПЭМ-Б 250);
  • Generation of digital signals of intermediate or limit positions of valve trim to be transferred through RS-485 interface (ПЭМ-А 100, ПЭМ-Б 250);
  • Generation of discrete signalsof intermediate or limit positions of valve trim to be transferred through RS-485 interface (ПЭМ-А 100, ПЭМ-Б 250);
  • Generation of discreet or digital signals of state of torque switches of start-up/shut-offto be transferred through RS-485 interface (ПЭМ-А 100, ПЭМ-Б 250).

Key features:

  • The electric drives ensure compliance with the declared specification withsupply voltage deviation of -15% to +10% from the nominal value;
  • Output shaft run-out of the electric drive is 15º at most, which extends service life of the operated stop gate.
  • The design of the limit and travel switches provides for its once-only adjustment during on-site mounting.
  • Service life: 15 years.
  • Operation in extreme conditions: over-temperatures, extreme dust and vibration; these electric drives are safe, easily maintained and reparable.
Type of electric drive Output shaft torque, Nm Nominal time of full travel of output shaft, rev Nominal full travel of output shaft, rev Number of output shaft revolutions, max. (min.), rev Output shaft speed, rev/min Voltage (frequency supply)
ПЭМ-А 25-70; 70-110 10(1); 45 (10) 380 V (50 Hz)
ПЭМ-Б 100-300 6(1); 45 (6);
60 (35)
25; 50 380 V (50 Hz)
ПЭМ-В 250-630; 500-1000 36 (6); 216(36) 24; 48 380 V (50 Hz)
ПЭМ-А-IIBT4; ПЭМ2-А-IIВТ4 25-70; 70-110 10(1); 45 (10) 12; 24 380 V (50 Hz)
ПЭМ-Б-IIBT4; ПЭМ2-Б-IIВТ4 100-300 6(1); 45 (6);
60 (35)
25; 50 380 V (50 Hz)
ПЭМ2-В-IIBT4 250-630; 500-1000 36 (6); 36(216) 25; 50 380 V (50 Hz)
ПЭМ-А 100 40-100 2-511 7; 12; 22; 48; 96 380 V (50 Hz)
ПЭМ-Б 250 100-250 2-511 6; 12; 24; 48; 96 380 V (50 Hz)

2015-11-16 14-49-38 ПЭМ.docx [Compatibility Mode]